Overview

CProgIODemux routes one notify-capable input to one selected output. A scalar uint32 control IO selects the active output with zero-based indexes. On start the input value is written to the selected output. Non-selected outputs retain their previous values.

Configuration

Kconfig

  • CONFIG_DAWN_PROG_IODEMUX: enables the program.

YAML

programs:
  - id: demux_value
    type: iodemux
    config:
      control: selected_output
      input: source_value
      outputs: [target0, target1]

Doxygen