Modbus RTU Protocol
Component Type: Protocol
Status: Implemented
Overview
CProtoModbusRtu is a Modbus RTU slave protocol object that maps
NxModbus callbacks to Dawn IO.
Implementation
Supported register group types:
MODBUS_TYPE_COIL,MODBUS_TYPE_COIL_PACKED,MODBUS_TYPE_DISCRETE,MODBUS_TYPE_DISCRETE_PACKED,MODBUS_TYPE_INPUT,MODBUS_TYPE_HOLDING,MODBUS_TYPE_SEEKABLE.Overlap in the same register class is rejected at configuration (assert + error return).
MODBUS_TYPE_COIL_PACKEDuses Modbus bit encoding for bool IO: 0 -> bit 0, nonzero -> bit 1.MODBUS_TYPE_INPUTandMODBUS_TYPE_HOLDINGsupport mixed-width IO (16/32/64-bit) inside one group.Multi-register scalar values are transferred as one contiguous register payload in big-endian register order, so 32/64-bit IO values preserve their numeric value when written and read back.
Multi-dimensional IO is flattened element-by-element in declaration order; the protocol is responsible for reconstructing the typed payload on reads and splitting it back into registers on writes.
Endianness and packing are Modbus protocol rules, not Dawn internal layout rules. External clients should mirror this wire contract.
coilandholdinggroups may bind write-only Dawn IOs. In that case Modbus reads return the protocol’s cached last written value because the target IO itself has no read path.Register shadow buffer is also used for write-only Modbus outputs.
Seekable IO and file records
type: seekable and MODBUS_TYPE_SEEKABLE = 7 remain the public
mapping for seekable IO. NxModbus supplies Read File Record (FC20,
0x14) and Write File Record (FC21, 0x15), including PDU parsing,
validation, responses, and exceptions. Dawn registers file_cb and maps
its file and record arguments to the IO’s existing offset read/write API.
Reference type is 6. Both RTU and TCP use this implementation.
Existing descriptor fields and binding addresses are retained:
registers:
- type: seekable
start: 4096
config: 256
bindings: [descriptor0, descriptor1, capabilities0]
config is the window width in words (8 when zero or omitted). Each IO
reserves config + 1 positions, so these binding addresses remain 4096,
4353, and 4610. Seekable allocations occupy file-number space independently
of coils and registers. Overlapping seekable allocations are rejected.
For a binding at zero-based address A, file A + 1 starts with IO
byte zero. Each reserved file carries 10,000 two-byte records. Subsequent
files extend the same IO’s byte range, preserving access to IOs larger than
20,000 bytes. The offset for a request is:
byte_offset = (file_number - A - 1) * 20000 + record_number * 2
Each request must stay within one file; clients split requests at file boundaries. All allocated file numbers must fit 1–65535. The backing IO must fit the allocation. This is Dawn’s mapping of IOs into the file-number space served by the standard functions.
File-record payloads contain IO bytes in their original order. For example,
IO bytes 12 34 are carried in the record 0x1234. Reads zero-fill
unused bytes and records past the IO’s current end, within its allocation,
preserving the previous seekable window behavior. Each request specifies
its offset; reads do not advance a shared server cursor.
Writes carry complete two-byte records and call the IO’s existing offset write method. FileIO and writable descriptor slots start a replacement on a write at offset zero. FileIO write-once permissions still lock after the first write. Errors from the backing IO are returned through NxModbus. FC20/FC21 do not convey an exact byte length, truncate an empty file, or provide begin/finish/abort operations. Applications transferring an odd number of bytes must account for the final record’s padding in their data format; both bytes of a write record are passed to the IO.
NxModbus supports at most 121 records per single-group FC20 request and 122 per FC21 request. The host helper uses 120-record writes because the current NxModbus RTU receiver drops an exactly full 256-byte frame.
CONFIG_DAWN_PROTO_MODBUS_SEEKABLE automatically enables the NxModbus
FC20/FC21 handlers when Modbus and seekable IO are enabled. Update firmware
and clients together: seekable wire access now uses file records instead
of holding-register windows and seek-control writes. The Python console
keeps its window-sized results and tracks its cursor locally; see
dawnpy-modbus.
Register Management
The mapping between Dawn IO objects and Modbus registers is handled by the
CProtoModbusRegs base class. This logic is shared across all Modbus
transport implementations (RTU, TCP).
Configuration
Kconfig
CONFIG_DAWN_PROTO_MODBUS: enables Modbus protocol support.CONFIG_DAWN_PROTO_MODBUS_RTU: enables the RTU transport.CONFIG_DAWN_PROTO_MODBUS_RTU_PATH: default RTU device path.CONFIG_DAWN_PROTO_MODBUS_RTU_BAUD: default RTU baudrate.CONFIG_DAWN_PROTO_MODBUS_RTU_ADDR: default Modbus slave address.CONFIG_DAWN_PROTO_MODBUS_RTU_PARITY: default RTU parity mode.
YAML
protocols:
- id: modbus1
type: modbus_rtu
config:
path: "/dev/ttyS1"
registers:
- type: coil
config: 0
start: 0
bindings:
- coil1
- coil2
- type: discrete_packed
config: 0
start: 100
bindings:
- di1
- di2
- di3
- type: holding
config: 0
start: 1000
bindings:
- holding1
- type: input
config: 0
start: 2000
bindings:
- input1
Supported fields:
config.path: serial device path.config.registers: register group definitions.
Supported registers[*].type values:
coildiscretecoil_packeddiscrete_packedinputholdingseekable
Supported registers[*] fields:
type: register group type.config: private group configuration; window width forseekable.start: first register/bit address, or zero-based seekable allocation address.bindings: IOs mapped into the group.
External Control
ControlIO: supported.
CProtoModbusRtu supports runtime start/stop control through CIOControl.
When stopped, Modbus polling/service loop is inactive. When started again,
register servicing resumes.
TriggerIO: not supported.