Modbus TCP Protocol

Component Type: Protocol

Status: Implemented

Overview

CProtoModbusTcp is a Modbus TCP slave protocol object that maps NxModbus callbacks to Dawn IO.

Implementation

  • Supported register group types: MODBUS_TYPE_COIL, MODBUS_TYPE_COIL_PACKED, MODBUS_TYPE_DISCRETE, MODBUS_TYPE_DISCRETE_PACKED, MODBUS_TYPE_INPUT, MODBUS_TYPE_HOLDING, MODBUS_TYPE_SEEKABLE.

  • Overlap in the same register class is rejected at configuration (assert + error return).

  • MODBUS_TYPE_COIL_PACKED uses Modbus bit encoding for bool IO: 0 -> bit 0, nonzero -> bit 1.

  • MODBUS_TYPE_INPUT and MODBUS_TYPE_HOLDING support mixed-width IO (16/32/64-bit) inside one group.

  • Multi-register scalar values are transferred as one contiguous register payload in big-endian register order, so 32/64-bit IO values preserve their numeric value when written and read back.

  • Multi-dimensional IO is flattened element-by-element in declaration order; the protocol is responsible for reconstructing the typed payload on reads and splitting it back into registers on writes.

  • Endianness and packing are Modbus protocol rules, not Dawn internal layout rules. External clients should mirror this wire contract.

  • coil and holding groups may bind write-only Dawn IOs. In that case Modbus reads return the protocol’s cached last written value because the target IO itself has no read path.

  • Register shadow buffer is also used for write-only Modbus outputs.

Seekable IO and file records

type: seekable uses NxModbus’s standard FC20/FC21 handlers and the same file_cb mapping as RTU. See Seekable IO and file records for file numbers, byte offsets, record sizes, permissions, and client compatibility.

Register Management

The mapping between Dawn IO objects and Modbus registers is handled by the CProtoModbusRegs base class. This logic is shared across all Modbus transport implementations (RTU, TCP).

Configuration

Kconfig

  • CONFIG_DAWN_PROTO_MODBUS: enables Modbus protocol support.

  • CONFIG_DAWN_PROTO_MODBUS_TCP: enables the TCP transport.

  • CONFIG_DAWN_PROTO_MODBUS_TCP_PORT: default TCP listen port.

  • CONFIG_DAWN_PROTO_MODBUS_TCP_ADDR: default Modbus slave address.

YAML

protocols:
  - id: modbus1
    type: modbus_tcp
    config:
      port: 502
      registers:
        - type: coil
          config: 0
          start: 0
          bindings:
            - coil1
            - coil2
        - type: discrete_packed
          config: 0
          start: 100
          bindings:
            - di1
            - di2
            - di3
        - type: holding
          config: 0
          start: 1000
          bindings:
            - holding1
        - type: input
          config: 0
          start: 2000
          bindings:
            - input1

Supported fields:

  • config.port: TCP listen port.

  • config.registers: register group definitions.

Supported registers[*].type values:

  • coil

  • discrete

  • coil_packed

  • discrete_packed

  • input

  • holding

  • seekable

Supported registers[*] fields:

  • type: register group type.

  • config: private group configuration; window width for seekable.

  • start: first register/bit address, or zero-based seekable allocation address.

  • bindings: IOs mapped into the group.

External Control

ControlIO: supported.

CProtoModbusTcp supports runtime start/stop control through CIOControl. When stopped, Modbus polling/service loop is inactive. When started again, register servicing resumes.

TriggerIO: not supported.