Modbus TCP Protocol
Component Type: Protocol
Status: Implemented
Overview
CProtoModbusTcp is a Modbus TCP slave protocol object that maps
NxModbus callbacks to Dawn IO.
Implementation
Supported register group types:
MODBUS_TYPE_COIL,MODBUS_TYPE_COIL_PACKED,MODBUS_TYPE_DISCRETE,MODBUS_TYPE_DISCRETE_PACKED,MODBUS_TYPE_INPUT,MODBUS_TYPE_HOLDING,MODBUS_TYPE_SEEKABLE.Overlap in the same register class is rejected at configuration (assert + error return).
MODBUS_TYPE_COIL_PACKEDuses Modbus bit encoding for bool IO: 0 -> bit 0, nonzero -> bit 1.MODBUS_TYPE_INPUTandMODBUS_TYPE_HOLDINGsupport mixed-width IO (16/32/64-bit) inside one group.Multi-register scalar values are transferred as one contiguous register payload in big-endian register order, so 32/64-bit IO values preserve their numeric value when written and read back.
Multi-dimensional IO is flattened element-by-element in declaration order; the protocol is responsible for reconstructing the typed payload on reads and splitting it back into registers on writes.
Endianness and packing are Modbus protocol rules, not Dawn internal layout rules. External clients should mirror this wire contract.
coilandholdinggroups may bind write-only Dawn IOs. In that case Modbus reads return the protocol’s cached last written value because the target IO itself has no read path.Register shadow buffer is also used for write-only Modbus outputs.
Register Management
The mapping between Dawn IO objects and Modbus registers is handled by the
CProtoModbusRegs base class. This logic is shared across all Modbus
transport implementations (RTU, TCP).
Configuration
Kconfig
CONFIG_DAWN_PROTO_MODBUS: enables Modbus protocol support.CONFIG_DAWN_PROTO_MODBUS_TCP: enables the TCP transport.CONFIG_DAWN_PROTO_MODBUS_TCP_PORT: default TCP listen port.CONFIG_DAWN_PROTO_MODBUS_TCP_ADDR: default Modbus slave address.
YAML
protocols:
- id: modbus1
type: modbus_tcp
config:
port: 502
registers:
- type: coil
notify: 0
start: 0
bindings:
- coil1
- coil2
- type: discrete_packed
notify: 1
start: 100
bindings:
- di1
- di2
- di3
- type: holding
notify: 0
start: 1000
bindings:
- holding1
- type: input
notify: 0
start: 2000
bindings:
- input1
Supported fields:
config.port: TCP listen port.config.registers: register group definitions.
Supported registers[*].type values:
coildiscretecoil_packeddiscrete_packedinputholdingseekable
Supported registers[*] fields:
type: register group type.notify: enable change notification shadowing for the group.start: first register or bit address.bindings: IOs mapped into the group.
External Control
ControlIO: supported.
CProtoModbusTcp supports runtime start/stop control through CIOControl.
When stopped, Modbus polling/service loop is inactive. When started again,
register servicing resumes.
TriggerIO: not supported.